- 05 Sep, 2009 7 commits
-
-
Christof Schmitt authored
When the FCP channel returns a series of commands with the error status "test link", zfcp will send a series of ELS ADISC commands. This is technically no problem, but it is enough to only issue one test command per remote port. So, track whether a ELS ADISC command is already pending, and do not send a new one if there is already a pending command. Reviewed-by: Swen Schillig <swen@vnet.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Christof Schmitt authored
Using a bitwise OR to not set anything at all is pointless so remove the useless statement. Reviewed-by: Swen Schillig <swen@vnet.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Christof Schmitt authored
The default trace level is to only trace failed FSF commands. Thus it is not necessary to collect trace data for most FSF commands, since it will be thrown away later. Restructure the FSF/HBA trace infrastructure to first check the trace level in a inline function and only do the expensive data collection for matching trace levels. Reviewed-by: Swen Schillig <swen@vnet.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Christof Schmitt authored
The default trace level is to only trace failed SCSI commands. Thus it is not necessary to collect trace data for most SCSI commands since it will be thrown away later. Restructure the SCSI trace infrastructure to first check the trace level in a inline function and only do the expensive data collection for matching trace levels. Reviewed-by: Swen Schillig <swen@vnet.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Christof Schmitt authored
The struct zfcp_adapter includes everything related to the debug traces. This introduces dependences between the definitions in zfcp_def.h and zfcp_dbf.h. Move all debug related data structures to a new data structure to break those dependencies and manage the debug data in zfcp_dbf.[hc]. Reviewed-by: Swen Schillig <swen@vnet.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Swen Schillig authored
In certain error scenarios ports, rports are getting attached, validated and removed from the systems environment. Depending on the layer this occurs asynchronously. This patch fixes the few races which existed and ensures all references and cross references are cleared at the time they're invalid. In addition fc transports actions are only scheduled when required. Signed-off-by: Swen Schillig <swen@vnet.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Yanqing_Liu@Dell.com authored
This patch is to add DM support for next generation of Dell PowerVault storage array. Signed-off-by: Yanqing Liu <Yanqing_Liu@Dell.com> Acked-by: Chandra Seetharaman <sekharan@us.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
- 22 Aug, 2009 33 commits
-
-
James Bottomley authored
Novell is now funding SCSI work, so the MAINTAINERS file should reflect this. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Bump version to 3.04.11 Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Code cleanup of host page alloc and diag reset. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Do not set max_id value received from FW. Once SAS transport layer is introduced max_id value is missleading to SCSI mid layer. Use max_id to infinite value. logic of can queue of scsi host is changed. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Change config request timeout value to 30 seconds. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Handle insufficient resources status as similar to busy status. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Removed mptscsih_timer_expired. This timer is no more use. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Kashyap, Desai authored
Change DEFINED value of can queue for FC and SAS devices. Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Chandra Seetharaman authored
Reported-by: Rice Brown <rick.brown@oit.gatech.edu> Signed-Off-by: Chandra Seetharaman <sekharan@us.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
James Bottomley authored
Universally, SCSI functions assume the lengths fed in are those of the buffer to DMA data to, not the lengths of the data minus the header. scsi_vpd_inquiry() assumed the latter and got it wrong, so fix up all the functions to use the correct assumption (and fix a bug where INQUIRY in SCSI-2 dcannot go over 255). [jejb: Matthew posted an identical version of this at the same time I did] Signed-off-by: Matthew Wilcox <matthew@wil.cx> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Michael Reed authored
An IBM tape drive failed to complete a PERSISTENT RESERVE IN within the scsi cmd timeout. Error recovery was initiated and it sequenced from abort through taking the tape drive offline. The device was taken offline because it repeatedly responded to the TUR command issued by error recovery with a RESERVATION CONFLICT status. The tape drive was reserved to another system. This is perfectly legitimate response to TUR, and is one that an escalation of recovery is unlikely to clear. Further, escalation of recovery can have undesirable side effects on the operation of tape drives shared with other initiators. Instead of escalating recovery, error recovery should treat the RESERVATION CONFLICT response to the TUR as a good status, giving the issuer of the command the opportunity to handle the timeout and reservation conflict. Signed-off-by: Michael reed <mdr@sgi.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Jiri Slaby authored
In nsp_cs_config there is a wrong struct nsp_cs_configdata allocation. It allocates only sizeof(pointer to nsp_cs_configdata) for a whole structure. Add a dereference to the sizeof to allocate sizeof(nsp_cs_configdata). Signed-off-by: Jiri Slaby <jirislaby@gmail.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Davidlohr Bueso A authored
Verify that ch->dt is not NULL before using it. Signed-off-by: Davidlohr Bueso <dave@gnu.org> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Sage Weil authored
The allocated struct is manually zeroed after allocation, so avoid using the (broken) kzalloc mempool (which does not re-zero previously used items when they are returned to the pool). Acked-by: Brian King <brking@linux.vnet.ibm.com> Signed-off-by: Sage Weil <sage@newdream.net> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Giridhar Malavali authored
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Anirban Chakraborty authored
When the multiqueue mode fails to work, the driver falls back on single queue mode. This ensures that the firmware is reinitialized with single queue options and all the resources are readjusted accordingly. Signed-off-by: Anirban Chakraborty <anirban.chakraborty@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Andrew Vasquez authored
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Anirban Chakraborty authored
The interrupt handler clears the interrupt status register for response updates in the base queue while working in the multique mode. This could lead to missing interrupt for async events, mail box completions etc. as these are also handled in the base queue. The fix ensures that the interrupt bit is not cleared for response updates in the ISR when the driver is working in multiqueue mode. Signed-off-by: Anirban Chakraborty <anirban.chakraborty@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Andrew Vasquez authored
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Shyam Sundar authored
One byte added to make the IOCB structure satisfy size requirements. Signed-off-by: Shyam Sundar <shyam.sundar@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Santosh Vernekar authored
Signed-off-by: Santosh Vernekar <santosh.vernekar@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Lalit Chandivade authored
If vports are created and topology is changed to Loop only, the driver continuously gets a LIP reset occurred and keeps trying to enable the vport. Only manage requests during F_Port. Signed-off-by: Lalit Chandivade <lalit.chandivade@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Santosh Vernekar authored
Signed-off-by: Santosh Vernekar <santosh.vernekar@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Santosh Vernekar authored
The RSCN processing is skipped if the event received is global and vha is not recipient. Signed-off-by: Santosh Vernekar <santosh.vernekar@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Andrew Vasquez authored
Treat a global port-unavailable PORT_UPDATE (8014h) AEN as a loop-down event. For this case, within the FCoE domain, the 'logical' interface has been terminated, but the driver will not receive the classic LOOP_DOWN AEN. Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Ravi Anand authored
Signed-off-by: Ravi Anand <ravi.anand@qlogic.com> Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Chandra Seetharaman authored
Use scsi_dh_set_params() set parameters provided. Save the parameters in parse_hw_handler() and use it in parse_path(). Reported-by: Eddie Williams <Eddie.Williams@steeleye.com> Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com> Tested-by: Eddie Williams <Eddie.Williams@steeleye.com> Cc: Alasdair G Kergon <agk@redhat.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Chandra Seetharaman authored
Handle the parameters provided by user thru multipath. This handler expects only 2 parameters and their value can either be 0 or 1. This code originates from the old dm-emc.c file. Appropriate changes have been made to make it work in the new design. Reported-by: Eddie Williams <Eddie.Williams@steeleye.com> Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com> Tested-by: Eddie Williams <Eddie.Williams@steeleye.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Chandra Seetharaman authored
When we moved the device handler functionality from dm layer to SCSI layer we dropped the parameter functionality. This path adds an interface to scsi dh layer to set device handler parameters. Basically, multipath layer need to create a string with all the parameters and call scsi_dh_set_params() after it called scsi_dh_attach() on a device. If a device handler provides such an interface it will handle the parameters as it expects them. Reported-by: Eddie Williams <Eddie.Williams@steeleye.com> Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com> Tested-by: Eddie Williams <Eddie.Williams@steeleye.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
James Bottomley authored
Now that hot add works correctly, if a new device is added, we're still operating on stale enclosure data, so fix that by updating the enclosure diagnostic pages when we get notified of a device hot add Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
James Bottomley authored
Right at the moment, hot removal of a device within an enclosure does nothing (because the intf_remove only copes with enclosure removal not with component removal). Fix this by adding a function to remove the component. Also needed to fix the prototype of enclosure_remove_device, since we know the device we've removed but not the internal component number Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
James Bottomley authored
In a situation either with expanders or with multiple enclosure devices, hot add doesn't always work. This is because we try to find a single enclosure device attached to the host. Fix this by looping over all enclosure devices attached to the host and also by making the find loop recognise that the enclosure devices may be expander remote (i.e. not parented by the host). Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-
Brian King authored
ipr_cmd_label[] isn't big enough for an eight byte string plus terminator. Fix by shortening the string to seven bytes. Signed-off-by: Brian King <brking@linux.vnet.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
-