firewire: sbp2: provide fallback if mgt_ORB_timeout is missing
The Unit_Characteristics entry of an SBP-2 unit directory is not mandatory as far as I can tell. If it is missing, we would probably fail to log in into the target because firewire-sbp2 would not wait for status after it sent the login request. The fix moves the cleanup of tgt->mgt_orb_timeout into a place where it is executed exactly once before login, rather than 0..n times depending on the target's config ROM. With targets with one or more Unit_Characteristics entries, the result is the same as before. Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>