at76c50x-usb: fix oops on disconnect
flush_workqueue needs to be called instead of the generic one and the associated functions need to be modified to prevent re-adding themselves to the workqueue. The rx_tasklet is also killed in the small (?) chance it is scheduled. Signed-off-by: Jason Andryuk <jandryuk@gmail.com> Signed-off-by: Kalle Valo <kalle.valo@iki.fi> Signed-off-by: John W. Linville <linville@tuxdriver.com>