TWL4030: use *_SIH_CTRL.COR bit to determine whether to read or write ISR to clear
TWL4030 interrupt status register bits can be cleared in one of two ways: either by reading from the register, or by writing a 1 to the appropriate bit(s) in the register. This behavior can be altered at any time by the <twlmodule>_SIH_CTRL.COR register bit ("clear-on-read"). The TWL4030 TRM is deeply confused as to whether COR=1 means that the registers are cleared on reads, or cleared on writes. Peter De Schrijver <peter.de-schrijver> confirms that COR=1 means that the registers are cleared on read. So, for each TWL4030 SIH, check the value of the *_SIH_CTRL.COR bit, and if it is 1, use reads to clear the ISRs; if it is 0, use writes. Also, use WARN_ON() to warn if the read/write failed, and don't skip the rest of the initialization on failure either. Thanks to Peter for his help with this patch. Signed-off-by: Paul Walmsley <paul@pwsan.com> Signed-off-by: Tony Lindgren <tony@atomide.com>