Commit 7d7a09ea authored by Haojian Zhuang's avatar Haojian Zhuang Committed by Liam Girdwood

regulator: support list voltage in da903x

Make da903x driver to list voltage and count voltage.
Signed-off-by: default avatarHaojian Zhuang <haojian.zhuang@marvell.com>
Acked-by: default avatarMark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: default avatarEric Miao <eric.y.miao@gmail.com>
Signed-off-by: default avatarLiam Girdwood <lrg@slimlogic.co.uk>
parent f07768cb
......@@ -87,6 +87,10 @@ struct da903x_regulator_info {
int enable_bit;
};
static int da9034_ldo12_data[] = { 1700, 1750, 1800, 1850, 1900, 1950,
2000, 2050, 2700, 2750, 2800, 2850,
2900, 2950, 3000, 3050 };
static inline struct device *to_da903x_dev(struct regulator_dev *rdev)
{
return rdev_get_dev(rdev)->parent->parent;
......@@ -170,6 +174,17 @@ static int da903x_is_enabled(struct regulator_dev *rdev)
return !!(reg_val & (1 << info->enable_bit));
}
static int da903x_list_voltage(struct regulator_dev *rdev, unsigned selector)
{
struct da903x_regulator_info *info = rdev_get_drvdata(rdev);
int ret;
ret = info->min_uV + info->step_uV * selector;
if (ret > info->max_uV)
return -EINVAL;
return ret;
}
/* DA9030 specific operations */
static int da9030_set_ldo1_15_voltage(struct regulator_dev *rdev,
int min_uV, int max_uV)
......@@ -313,9 +328,18 @@ static int da9034_get_ldo12_voltage(struct regulator_dev *rdev)
return info->min_uV + info->step_uV * val;
}
static int da9034_list_ldo12_voltage(struct regulator_dev *rdev,
unsigned selector)
{
if (selector > ARRAY_SIZE(da9034_ldo12_data))
return -EINVAL;
return da9034_ldo12_data[selector] * 1000;
}
static struct regulator_ops da903x_regulator_ldo_ops = {
.set_voltage = da903x_set_ldo_voltage,
.get_voltage = da903x_get_voltage,
.list_voltage = da903x_list_voltage,
.enable = da903x_enable,
.disable = da903x_disable,
.is_enabled = da903x_is_enabled,
......@@ -325,6 +349,7 @@ static struct regulator_ops da903x_regulator_ldo_ops = {
static struct regulator_ops da9030_regulator_ldo14_ops = {
.set_voltage = da9030_set_ldo14_voltage,
.get_voltage = da9030_get_ldo14_voltage,
.list_voltage = da903x_list_voltage,
.enable = da903x_enable,
.disable = da903x_disable,
.is_enabled = da903x_is_enabled,
......@@ -334,6 +359,7 @@ static struct regulator_ops da9030_regulator_ldo14_ops = {
static struct regulator_ops da9030_regulator_ldo1_15_ops = {
.set_voltage = da9030_set_ldo1_15_voltage,
.get_voltage = da903x_get_voltage,
.list_voltage = da903x_list_voltage,
.enable = da903x_enable,
.disable = da903x_disable,
.is_enabled = da903x_is_enabled,
......@@ -342,6 +368,7 @@ static struct regulator_ops da9030_regulator_ldo1_15_ops = {
static struct regulator_ops da9034_regulator_dvc_ops = {
.set_voltage = da9034_set_dvc_voltage,
.get_voltage = da903x_get_voltage,
.list_voltage = da903x_list_voltage,
.enable = da903x_enable,
.disable = da903x_disable,
.is_enabled = da903x_is_enabled,
......@@ -351,6 +378,7 @@ static struct regulator_ops da9034_regulator_dvc_ops = {
static struct regulator_ops da9034_regulator_ldo12_ops = {
.set_voltage = da9034_set_ldo12_voltage,
.get_voltage = da9034_get_ldo12_voltage,
.list_voltage = da9034_list_ldo12_voltage,
.enable = da903x_enable,
.disable = da903x_disable,
.is_enabled = da903x_is_enabled,
......@@ -363,6 +391,7 @@ static struct regulator_ops da9034_regulator_ldo12_ops = {
.ops = &da903x_regulator_ldo_ops, \
.type = REGULATOR_VOLTAGE, \
.id = _pmic##_ID_LDO##_id, \
.n_voltages = (step) ? ((max - min) / step + 1) : 1, \
.owner = THIS_MODULE, \
}, \
.min_uV = (min) * 1000, \
......@@ -382,6 +411,7 @@ static struct regulator_ops da9034_regulator_ldo12_ops = {
.ops = &da9034_regulator_dvc_ops, \
.type = REGULATOR_VOLTAGE, \
.id = DA9030_ID_##_id, \
.n_voltages = (step) ? ((max - min) / step + 1) : 1, \
.owner = THIS_MODULE, \
}, \
.min_uV = (min) * 1000, \
......@@ -403,6 +433,7 @@ static struct regulator_ops da9034_regulator_ldo12_ops = {
.ops = &da9034_regulator_dvc_ops, \
.type = REGULATOR_VOLTAGE, \
.id = DA9034_ID_##_id, \
.n_voltages = (step) ? ((max - min) / step + 1) : 1, \
.owner = THIS_MODULE, \
}, \
.min_uV = (min) * 1000, \
......@@ -424,6 +455,7 @@ static struct regulator_ops da9034_regulator_ldo12_ops = {
.ops = &da9034_regulator_dvc_ops, \
.type = REGULATOR_VOLTAGE, \
.id = DA9035_ID_##_id, \
.n_voltages = (step) ? ((max - min) / step + 1) : 1, \
.owner = THIS_MODULE, \
}, \
.min_uV = (min) * 1000, \
......@@ -517,8 +549,10 @@ static int __devinit da903x_regulator_probe(struct platform_device *pdev)
}
/* Workaround for the weird LDO12 voltage setting */
if (ri->desc.id == DA9034_ID_LDO12)
if (ri->desc.id == DA9034_ID_LDO12) {
ri->desc.ops = &da9034_regulator_ldo12_ops;
ri->desc.n_voltages = ARRAY_SIZE(da9034_ldo12_data);
}
if (ri->desc.id == DA9030_ID_LDO14)
ri->desc.ops = &da9030_regulator_ldo14_ops;
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment