Commit 69d8d3eb authored by Clemens Ladisch's avatar Clemens Ladisch Committed by Jaroslav Kysela

[ALSA] mpu-401: do not require an ACK byte for the ENTER_UART command

The original MPU-401 does not send an ACK byte after processing the
ENTER_UART command, so we better do not try to wait for it.
Many clones get this wrong and do send an ACK, but when interpreting it
as MIDI, it is just a harmless Active Sensing message, and it is likely
to be read and discarded by the interrupt handler before the MIDI input
device is triggered.
Signed-off-by: default avatarClemens Ladisch <clemens@ladisch.de>
Signed-off-by: default avatarJaroslav Kysela <perex@suse.cz>
parent 11be265f
......@@ -271,7 +271,7 @@ static int snd_mpu401_do_reset(struct snd_mpu401 *mpu)
if (snd_mpu401_uart_cmd(mpu, MPU401_RESET, 1))
return -EIO;
if (!(mpu->info_flags & MPU401_INFO_UART_ONLY) &&
snd_mpu401_uart_cmd(mpu, MPU401_ENTER_UART, 1))
snd_mpu401_uart_cmd(mpu, MPU401_ENTER_UART, 0))
return -EIO;
return 0;
}
......