Commit 6303e74c authored by Joachim Fenkes's avatar Joachim Fenkes Committed by Roland Dreier

IB/ehca: Fix CQE flags reporting

The driver was reporting CQE flags in the wrong bit positions, causing
consumers to miss incoming immediate data.
Signed-off-by: default avatarJoachim Fenkes <fenkes@de.ibm.com>
Signed-off-by: default avatarRoland Dreier <rolandd@cisco.com>
parent d706834d
......@@ -786,7 +786,11 @@ repoll:
wc->slid = cqe->rlid;
wc->dlid_path_bits = cqe->dlid;
wc->src_qp = cqe->remote_qp_number;
wc->wc_flags = cqe->w_completion_flags;
/*
* HW has "Immed data present" and "GRH present" in bits 6 and 5.
* SW defines those in bits 1 and 0, so we can just shift and mask.
*/
wc->wc_flags = (cqe->w_completion_flags >> 5) & 3;
wc->ex.imm_data = cpu_to_be32(cqe->immediate_data);
wc->sl = cqe->service_level;
......