Commit 15fe25ca authored by Jean Delvare's avatar Jean Delvare Committed by Greg Kroah-Hartman

hwmon: Fix documentation typos

Fix typos in hardware monitoring documentation.
Signed-off-by: default avatarJean Delvare <khali@linux-fr.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>
parent 2ca7b961
...@@ -17,7 +17,7 @@ Thanks to Kris Chen from Fintek for answering technical questions and ...@@ -17,7 +17,7 @@ Thanks to Kris Chen from Fintek for answering technical questions and
providing additional documentation. providing additional documentation.
Thanks to Chris Lin from Jetway for providing wiring schematics and Thanks to Chris Lin from Jetway for providing wiring schematics and
anwsering technical questions. answering technical questions.
Description Description
......
...@@ -26,7 +26,7 @@ fan control mode). ...@@ -26,7 +26,7 @@ fan control mode).
Temperatures are measured in degrees Celsius and measurement resolution is 1 Temperatures are measured in degrees Celsius and measurement resolution is 1
degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when
the temperature gets higher than high limit; it stays on until the temperature the temperature gets higher than high limit; it stays on until the temperature
falls below the Hysteresis value. falls below the hysteresis value.
Fan rotation speeds are reported in RPM (rotations per minute). An alarm is Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
triggered if the rotation speed has dropped below a programmable limit. Fan triggered if the rotation speed has dropped below a programmable limit. Fan
...@@ -67,9 +67,9 @@ Thermal Cruise mode ...@@ -67,9 +67,9 @@ Thermal Cruise mode
If the temperature is in the range defined by: If the temperature is in the range defined by:
pwm[1-4]_target - set target temperature, unit millidegree Celcius pwm[1-4]_target - set target temperature, unit millidegree Celsius
(range 0 - 127000) (range 0 - 127000)
pwm[1-4]_tolerance - tolerance, unit millidegree Celcius (range 0 - 15000) pwm[1-4]_tolerance - tolerance, unit millidegree Celsius (range 0 - 15000)
there are no changes to fan speed. Once the temperature leaves the interval, there are no changes to fan speed. Once the temperature leaves the interval,
fan speed increases (temp is higher) or decreases if lower than desired. fan speed increases (temp is higher) or decreases if lower than desired.
......