Ivo van Doorn authored
The TXD_W0_CIPHER field is a 1-bit field. It only acts as boolean value to indicate if the frame must be encrypted or not. The way rt2x00_set_field32() worked it would grab the least signifcant bit from txdesc->cipher and use that as value. Because of that WEP 64 and TKIP worked since they had odd-numbered values, while WEP 128 and AES were even numbers and didn't work. Correctly booleanize the txdecs->cipher value to allow the hardware to encrypt the outgoing data. After this we can enable HW crypto by default again. Signed-off-by: Ivo van Doorn <IvDoorn@gmail.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>