Clemens Ladisch authored
Upstream-commit-id: df91bc23 When changing the sample rate, the CMI8788's master clock output becomes unstable for a short time. The AK4396 needs the master clock to do SPI writes, so writing to an AK4396 control register directly after a sample rate change will garble the value. In our case, this leads to the DACs being misconfigured to I2S sample format, which results in a wrong output level and horrible distortions on samples louder than -6 dB. To fix this, we need to wait until the new master clock signal has become stable before doing SPI writes. Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Takashi Iwai <tiwai@suse.de> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
b7bacf78