Jordan Crouse authored
When we set the MFGPT timer tick, there is a chance that we'll immediately assert an event. If for some reason the IRQ routing for this clock has been setup for some other purpose, then we could end up firing an interrupt into the SMM handler or worse. This rearranges the timer tick init function to initalize the handler before we set up the MFGPT clock to make sure that even if we get an event, it will go to the handler. Furthermore, in the handler we need to make sure that we clear the event, even if the timer isn't running. Signed-off-by: Jordan Crouse <jordan.crouse@amd.com> Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Acked-by: Ingo Molnar <mingo@elte.hu> Tested-by: Arnd Hannemann <hannemann@i4.informatik.rwth-aachen.de>
667984d9