Clemens Ladisch authored
In receive contexts, reject packets with header_length==0. This would be an instruction to queue zero packets which would not make sense. This prevents a division by zero in the OHCI driver. Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
4ba1d9c0