Mark Brown authored
At present it is not possible for machine constraints to disable regulators which have been left on when the system starts, for example as a result of fixed default configurations in hardware. This means that power may be wasted by these regulators if they are not in use. Provide intial support for this with a late_initcall which will disable any unused regulators if the machine has enabled this feature by calling regulator_has_full_constraints(). If this has not been called then print a warning to encourage users to fully specify their constraints so that we can change this to be the default behaviour in future. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
ca725561