Commit 15fe25ca authored by Jean Delvare's avatar Jean Delvare Committed by Greg Kroah-Hartman

hwmon: Fix documentation typos

Fix typos in hardware monitoring documentation.
Signed-off-by: default avatarJean Delvare <khali@linux-fr.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>
parent 2ca7b961
......@@ -17,7 +17,7 @@ Thanks to Kris Chen from Fintek for answering technical questions and
providing additional documentation.
Thanks to Chris Lin from Jetway for providing wiring schematics and
anwsering technical questions.
answering technical questions.
Description
......
......@@ -26,7 +26,7 @@ fan control mode).
Temperatures are measured in degrees Celsius and measurement resolution is 1
degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when
the temperature gets higher than high limit; it stays on until the temperature
falls below the Hysteresis value.
falls below the hysteresis value.
Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
triggered if the rotation speed has dropped below a programmable limit. Fan
......@@ -67,9 +67,9 @@ Thermal Cruise mode
If the temperature is in the range defined by:
pwm[1-4]_target - set target temperature, unit millidegree Celcius
pwm[1-4]_target - set target temperature, unit millidegree Celsius
(range 0 - 127000)
pwm[1-4]_tolerance - tolerance, unit millidegree Celcius (range 0 - 15000)
pwm[1-4]_tolerance - tolerance, unit millidegree Celsius (range 0 - 15000)
there are no changes to fan speed. Once the temperature leaves the interval,
fan speed increases (temp is higher) or decreases if lower than desired.
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment