clockevents: prevent endless loop in periodic broadcast handler
commit d4496b39 upstream The reprogramming of the periodic broadcast handler was broken, when the first programming returned -ETIME. The clockevents code stores the new expiry value in the clock events device next_event field only when the programming time has not been elapsed yet. The loop in question calculates the new expiry value from the next_event value and therefor never increases. Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Ingo Molnar <mingo@elte.hu> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>